Oct 22 – 27, 2023
Lahan Select Gyeongju, South Korea
Asia/Seoul timezone

MEASURING AND CONTROL EQUIPMENT ON THE RFSOC FOR HOBICAT FACILITY

Oct 25, 2023, 2:34 PM
4m
Poster Measurement and control Posters

Description

Controlling SRF cavities in CW mode in the presence of mechanical disturbances, as well as in the presence of noisy detectors, makes control still a challenge. Internal cavity features such as Lorentzian forces are well understood and predictable, but also make control difficult. An inexpensive solution for compact accelerators that can accommodate many algorithms simultaneously on a single board at an affordable price is RFSoC. Their analog circuits are not yet accurate. Nevertheless, a significant reduction in development time can be achieved through an integrated architecture, as well as development tools available on the market.
The following will present the RFSoC control hardware with a focus on basic functions, implemented primarily as a firmware solution. The scope of functions is as follows: VNA measurements to determine resonator quality factor and S-parameters, PLL, control in the presence of noisy detector data, and adaptive RF/piezo control. The results of their tests on the Hobicat test facility will be shown.

Keyword RFSoC

Primary authors

Andriy Ushakov (Helmholtz-Zentrum Berlin) Dr Axel Neumann (Helmholtz Zentrum Berlin) Dr Pablo Echevarria Fernandez (Helmholtz Zentrum Berlin)